SECTION 3 - TROUBLESHOOTING

3-8

– JLG Sizzor –

3120768

Table 3-5. Flash Code Troubleshooting Messages

CODE

MESSAGE

REMEDY

1 Flash

Internal fault

Replace MOS90

2 Flashes*

Check enable wiring
Check for correct start up sequence
Check that both directions are not selected

Retry
Retry
Select only one direction

3 Flashes

Check power and control wiring for shorts
Replace controller

Rectify

4Flashes

Check direction contactor tips
Check power wiring for shorts
Check motor for armature to field shorts
Check for shorts to frame and battery leakage
Replace controller

Free/change tips
Rectify
Rectify
Rectify

5 Flashes

Check contactor tips
Check contactor for mechanical operation and coil
check power and control wiring
Check motor
Replace controller

Repair/replace
Repair/replace
Rectify
Rectify

6 Flashes

Check operation of hand controller with Test Sequence
Check pot operation with voltmeter for voltage at minimum
setting
Replace controller

Rectify/replace
Adjust as necessary or replace

7 Flashes

Check battery voltage with voltmeter
Check power connections, fuses, etc.
Check for battery leakage to frame
Replace controller

Change/charge battery
Repair or replace
Rectify

8 Flashes

Check current draw
Check mounting and heat sinking of controller

Rectify
Rectify

10 Flashes

Check tachometer wiring
Check speed tachometer
Replace tachometer

Repair
Rectify

11 Flashes

Recycle emergency stop switch
Check pin voltage

Replace tachometer PC board

NOTE: If the machine is operated at a very slow speed or stalled when climbing a grade of 20% or greater, a 10 flash fault will

occur. recycle the emergency stop switch to recover.

NOTE: All flash codes must be checked with unit switched to platform control

* If speed switch is turned 25% - 50% toward full speed, Sevcon controller will give a 2 flash fault indicating a procedure
fault. If, while 2 flash fault is being indicated, the speed control knob is turned to less then 25% the 2 flash fault will stop
and LED will come on steady, indicating controller operational.