SECTION 1 - SPECIFICATIONS

1-4

– JLG Lift –

3121139

Drive (Elevated): Test should be done on a smooth level
surface. Drive Select Switch should be set to High Engine.
Results should be recorded for a 50 ft. course. Drive For-
ward, Record Time. Drive Reverse, Record Time.

Platform Rotate: Platform level and completely rotated
one direction. Rotate the opposite direction, Record Time.
Rotate the other direction, Record Time.

Articulating Jib: Platform level and centered with the
boom. Start with the Jib down. Jib Up, Record Time. Jib
Down, Record Time.

Test Notes

1. Stop watch should be started with the function, not

with the controller or switch.

2. All speed tests are run from the platform. These

speeds do not reflect the ground control operation.

3. The platform speed knob control must be at full

speed (turned clockwise completely).

4. Function speeds may vary due to cold, thick hydrau-

lic oil. Test should be run with the oil temperature
above 100° F (38° C).

5. Some flow control functions may not work with the

speed knob clicked into the creep position.

1.7 TORQUE REQUIREMENTS

1.8 LUBRICATION

Hydraulic Oil

NOTE: Hydraulic oils must have anti-wear qualities at least

to API Service Classification GL-3, and sufficient
chemical stability for mobile hydraulic system ser-
vice. JLG Industries recommends Mobilfluid 424
hydraulic oil, which has an SAE viscosity index of
152.

NOTE: When temperatures remain consistently below 20

degrees F. (-7 degrees C.), JLG Industries recom-
mends the use of Mobil DTE13.

Aside from JLG recommendations, it is not advisable to
mix oils of different brands or types, as they may not con-
tain the same required additives or be of comparable vis-
cosities. If use of hydraulic oil other than Mobilfluid 424 is
desired, contact JLG Industries for proper recommenda-
tions.

Table 1-12. Torque Requirements

Description

Torque Value

(Dry)

Interval Hours

Wheel Lugs

300 ft. lbs.

(407 Nm)

150

Swing Bearing Bolts

190 ft. lbs.

(258 Nm)

50/600*

Starter Solenoid

Contacts

Coil

95 in. lbs. (9.5 Nm)

40 in. lbs. (4 Nm)

As required

*Check swing bearing bolts for security after first 50 hours
of operation and every 600 hours thereafter. (See Swing
Bearing in Section 3.)

NOTE: When maintenance becomes necessary or a fas-

tener has loosened, refer to the Torque Chart to
determine proper torque value.

Table 1-13. Hydraulic Oil

Hydraulic System

Operating

Temperature Range

S.A.E. Viscosity

Grade

+0° to + 180° F

(-18° to +83° C)

10W

+0° to + 210° F

(-18° to +99° C)

10W-20, 10W30

+50° to + 210° F

(+10° to +99° C

20W-20

Table 1-14. Mobilfluid 424 Specs

SAE Grade

10W30

Gravity, API

29.0

Density, Lb/Gal. 60°F

7.35

Pour Point, Max

-46

°F (-43°C)

Flash Point, Min.

442

°F (228°C)

Viscosity

Brookfield, cP at -18°C

2700

at 40° C

55 cSt

at 100° C

9.3 cSt

Viscosity Index

152