Description of terminals, Description of jumpers, Parallel connection – 2N Door intercom 2N Helios - Manual, 1322 v3.0 User Manual

Page 28

Advertising
background image

28

Description of Terminals

GND

This terminal protects 2N® Helios against static electricity damage.

SW1

Switch 1 designed primarily for electric door lock control.

LIGHT

These two terminals are connected to the 12V power supply with arbitrary
polarity. The power supply can feed the electric lock too.

LINE

These two terminals are connected to the analogue telephone line with
any polarity.

VIDEO

- Video signal output – used only if a camera unit is included. The coaxial

cable is connected with an internal conductor to

+,

with shielding to

-.

+

Description of Jumpers

Connector (8)

Here connect the current call indicator (LED).

Write-protection (if the jumper is mounted).

do not connect

Microphone sensitivity reduction (mount the jumper for noisy

environments).

Camera setting – connector (18): refer to the instructions enclosed to the camera
unit.

Parallel Connection

Parallel connection of multiple telephone sets was commonly used in the era in

which telephone lines were rare, It carries unnecessary risks to connect the unit in this
way. It is in no case recommended to connect 2N® Helios in parallel to another
telephone or another 2N® Helios door communicator. It is neither admissible to use
equipment that switches one line between two or more sets (intelligent double branch,
etc.).