2N® Mobile Audio Gateway

Basic Functions

· The 2N

®

Mobile

Audio

Gateway

(hereinafter MAG) is designed to
automatically answer a call from the

GSM mobile network and transfer the
caller’s voice to audio output. It is

designed to be connected to the input of

a PA exchange or similar device

intended for voice reproduction.

· The device is equipped with a switching

contact relay for activation of the
exchange during an ongoing call.

2N® Mobile Audio Gateway Installation and Connection


· Proper location

Install MAG with respect to a good mobile
network signal strength.

Place MAG out of range of sensitive
devices

and

human

bodies

for

electromagnetic interference reasons.
MAG is designed for indoor use. Do not

place it near heat sources and on direct
solar radiation. It may not be exposed to

rain, flowing water and moisture,
aggressive gas, solvents etc.

· External Antenna Connection

Screw the antenna cord into the SMA

antenna

connector.

Tighten

the

antenna connector gently with your

hand, never use a wrench!

· SIM card Installation

Slot for SIM card is placed on the
connector panel. Make sure your SIM

card is not PIN protected. Insert the
SIM card to the slot according to the

picture. If you wish to use PIN
protection, enter the PIN code into

MAG before the SIM is inserted. Use
the configuration tool.

· Connection of audio input to MAG

Audio signal output runs to a 3.5mm

mono jack on the side of the antenna
connector. You can use the supplied

cable, fitted with jacks on both ends, to
connect the input connector of the
connected device. If the connected

device is fitted with a different type of
input connector, it is necessary to fit it

with a suitable adaptor or other cable.

· Connection of switching relay

To activate the connected device, you
can use a switching contact relay run

to a connector; the mate of this
connector is supplied with the device.

The relay is closed during an ongoing
connection to the GSM network. The

relay is used for signaling, and cannot
be used for switching mains voltage!

(see technical parameters)

· Battery installation

Insert four pieces of rechargeable
battery NiMh size AA into the covered

compartment on the back side of the
gateway. Refer to the symbols in the

battery space for proper battery
placement and polarity. Use mentioned

type of batteries only!
Mains Supply Connection

MAG is 12V DC voltage powered.
Connect the attached power adapter

(12V/1A DC) to the power supply
connector. After connection, switch on

MAG with the power switch on the right
hand side of connector panel.

· MAG configuration

It is not necessary to configure the

device for basic MAG operation.
Configuration is necessary if a PIN code

is used to protect the SIM card, or if
you need to define the numbers from

which it is possible to control the MAG
and so on.

Do not activate the power supply until the antenna is connected to
EasyGate to avoid the GSM module damage.

2N® Mobile Audio Gateway Connection Layout

Use of the device

· When there is an incoming call, MAG

automatically picks up the call and
connects the audio output with the

incoming GSM voice channel.

· It also closes relay contacts connected to

the relay connector. This enables
activation of the connected audio device

and reproduction of the caller’s voice.

· The state of the ongoing call is signalled

by the LED Audio connection.

· At the end of the call by the caller, the

MAG goes into standby mode.

Configuration via USB

· The device is fully functional in the

default configuration. If you don’t need a

special setting, it is not necessary to
configure the device.

· For configuration by PC, you must install

the PCManager UNI program. Connect

the MAG by USB cable to the PC.

· After connection, a virtual series port is

created (USB serial port, FTDI) through
which the PCManager connects to the

gateway.

· When setting up PCManager, it is

necessary to select the number of the

virtual series port.

· Using PCManager, you can:
- Enter the PIN of the SIM card used

(protection)

- Permit calls from selected numbers only

(GSM routing table)

- Configure output volume (telephone line)

- Configure parameters of GSM connection,

especially roaming (GSM&SIM)

- Upgrade firmware - only with special FW

for MAG!

Other

parameters

configurable

via

PCManager are intended for the GSM

gateway. Do not change their setting.


Be careful when setting up roaming, which is permitted in the factory setting,

and if the gateway operates in this mode, incoming calls will be billed at the
relevant tariff!

Indication LEDs

Power

supply

Blue light – mains supply

Yellow light – battery supply

GSM

Network

Blue flashes – logged out
Blue light – logged in

Audio

connection

No light – standby

Yellow light – call in progress

PC

connection

Green light – PC connection active

During configuration by USB

interface

Signal

strength

Signal strength indication
Four levels of signal displayed

Power
adapter

Relay

contact

Not used

SIM

Switch
ON/OFF

PC (USB)

Advertising