2N Omega series - Configuration Tool manual v1.10 User Manual
Page 107

107
2.15.5. Types of Establishing Connection
It is possible to establish connection with an 2N
®
OMEGA Lite PBX to be
supervised:
automatically; or
manually.
2.15.6. AUTOMATIC CONNECTION
Settings of PBX To Be Supervised
Automatic connection can be used for a PBX provided that:
1. a DDI to the ISDN line ringing chart is reserved for remote supervision;
2. an ISDN MSN line is reserved for remote supervision;
3. a CO line is reserved for remote supervision;
4. the DISA to the ringing chart is used;
5. the modem connection detection is enabled in DISA.
Example of ringing chart set-up for types 1
– 3:
Interconnect remote supervision
…
Ring to operator
…
Wait
0
Hang up
…
Example of ringing chart set-up for types 4
– 5:
DISA
…
Wait
6
DISA END
…
Ring to operator
…
Wait
0
Hang up
…
Note:
With remote supervision type 5, you have to set the GLOBAL DATA
–
MODEM
– Modem switch to remote supervision in the programming
tool. The DISA tone may not be dialtone permanently.