Review of Programming Functions

3.2

56

Function
Number and Name

Value Range

Initializa-
tion Value

Notes, Explanations

981 – checking call

0 – disabled

1 – enabled

0

0 = off

1 = checking call in 1 minute; if previously off, the
checking call is enabled and the 3-day period
initialization is executed.

2 = on, first call in 2 hours

3 = on, first call in 3 days

Note: The voice menu recognises states 0 and 1 only,

but you may also enter values 2 and 3 to set the first

checking call time. The time that is left before the next

checking call is not announced in the voice menu.

991 – service password

up to 16 digits

12345

995 – software version check

-

This function spells present version of software.
Format: year-month-day

997 – password initialization for

all switches

enter the

service

password

The execution of these commands takes a rather
long time, typically approx. 5 seconds and 30
seconds at most. The ST is sending the
continuous tone while deleting the memory. Re-
enter the valid service password as the function
parameter (as protection against unintended
deletion if you enter a false function number).

998 – dialing memory deletion

for all buttons

enter the

service

password

999 – full initialization (incl.

service password!)

enter the

service

password

1

)

To parameter 904: The Automatic dialing without confirmation types 3 and (newly) 4
differ from each other in processing very short calls. Dialing 4 regards a call as successful
in all cases while dialing 3 only if the switch was activated. Since the switch is not
practically used for the ST, this difference is irrelevant.

2

)

A new implicit value, a lower probability of unintentional detection.

3

)

In the event of automatic dialing without confirmation, the ringing tone is detected and
terminated before the selected count of periods is reached, the call is regarded as
successful.

Note

Unless the ST is damaged electrically, the EEPROM guarantees 10 years of reliable
data storing at least.