Omega lite installation manual – 2N Omega Series - Instalation Manual User Manual

Page 19

Advertising
background image

2N

®

- OMEGA Lite

Installation manual


Installation manual

19

www.2n.cz

5.3. Module 1x external line / 1x internal line (order No 1880031)

Combined module for connecting one analogue external (J2) and one analogue

internal line (J3). The module allows the receipt of caller identification (Caller ID –
CLIP) using FSK modulation.

In the event of a power failure of the PBX, the module is equipped with a spill

relay which ensures the direct connection of the analogue external line to the
internal.


J1

- connector for connecting to motherboard (or extender module (the
connector is secured against incorrect connection by the blanking of
PIN 5,6,7,8).

J2

- connector RJ-45 (PIN 4-5) for connecting analogue external line.

J3

- connector RJ-45 (PIN 4-5) for connecting analogue internal line.

J4

- company servicing reanimation connector (SW for ALTERA).

J5

- connector for setting impedance (1-2= ETSI, 2-3= 600

Ω).



D1

- signalling LED ( picking up, ringing – external line).

D2

- signalling LED (picking up, ringing – internal line).


T1

-CO transformer


Note:

Equipment attached to connector J3 (telephone) must comply with the requirements

(standard – type approval) for equipment connected to the unified telephone system.


Advertising