Cardentered, Rfid card entered, Event.cardentered – 2N Helios IP Automation Manual v2.8 User Manual

Page 12: Parameters, Variables, Example

Advertising
background image

12

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Parameters

Code – define the numeric code.

Valid values:

numeric code – 12345, e.g.

SuppressTones – suppress sound signalling initiated by receiving of an invalid
numeric code. The parameter is optional.

Valid values:

0 – tones are not suppressed
1 – tones are suppressed (default value).

Variables

Code – the received numeric code which was the last to generate this event.

Example

Event generated by entering code 12345* on a keypad:

Event.CodeEntered: Code=12345

Event.CardEntered

The

block defines the event generated by tapping (swiping) of the RFID

CardEntered

card with the defined ID (for RFID card reader models only).

Parameters

Card – define the RFID card ID; refer to the Card Reader subsection in the 2N

®

.

Helios IP Configuration Manual

Valid values:

valid – any valid card (included in the intercom card list)
invalid – any invalid card
any - any valid or invalid card
card ID - defined card ID e.g. 3F00F34F78.

SuppressTones – suppress sound signalling initiated by detection of an invalid
card. The parameter is optional.

Valid values:

0 – tones are not suppressed
1 – tones are suppressed (default value).

Variables

Card – ID of the detected card which was the last to generate this event.