Chapter 5: troubleshooting – AirLive Ether-FSH2422W User Manual

Page 49

Advertising
background image

AirLive Ether-FSH2422W User’s Manual

43

Chapter 5: Troubleshooting

This section is intended to help the user solve the most common problems on the Ether-FSH2422W.

5-1 Incorrect connections

The switch port can auto-detect straight or crossover cable when the user links switch with other

Ethernet device. The RJ-45 connector should use correct UTP or STP cable. 10/100Mbps ports use 2

pairs twisted cable and Gigabit 1000T ports use 4 pairs twisted cable. If the RJ-45 connector is not

correctly pinned on right position then the link will fail. For fiber connection, please notice that fiber cable

mode should match the fiber module.

„

Faulty or loose cables

Look for loose or obviously faulty connections. If they appear to be OK, make sure the

connections are snug. If that does not correct the problem, try a different cable.

„

Non-standard

cables

Non-standard and miss-wired cables may cause numerous network collisions and

other network problem, and can seriously impair network performance. A category

5-cable tester is a recommended tool for every 100Base-T network installation.

„

Improper Network Topologies

It is important to make sure that users have a valid network topology. Common

topology faults include excessive cable length and too many repeaters (hubs) between

end nodes. In addition, the user should make sure that the network topology contains

no data path loops. Between any two ends nodes, there should be only one active

cabling path at any time. Data path loops will cause broadcast storms that will severely

impact the network performance.