1. Introduction

AirLive FE-200VD Manual

4

2. DI/DO connector:

DI/ DO: Connect to sensor in and alarm out devices
Pin Function Description
1 COM
2 RELAY-NO

Digital output implementation; Pin2 to COM (Pin1) is a
Photo-coupled relay on Normal Open status. External device can
directly connect to the terminals. However the current that will go
through the 2 nodes must not exceed 130mA. An external “Relay”
can also be connected to the terminals as an implementation. In
this case, current (or/and voltage) limitation is specified by the
external Relay.

3 GND
4 DIGITAL-IN

Connect to GND to activate, or leave floating (or unconnected) to
deactivate.

5 GND
6 DEFAULT

PIN with a short wire connecting two revert to factory default
settings.


3. Factory Default Reset
To restore factory default, please follow the steps:

1.

Unplug the power jack to turn off the camera

2.

Short pin 5 and pin 6 with a wire

3.

Plug in the power jack to turn on the camera. The power LED will start flashing
in a short while.

4.

Break the short when the LED starts quick flashing. Wait for a few minutes the
device should be set back to factory default.


Note:

Restoring the factory default setting will lose the all previous settings included IP

address forever. A user needs to run the IPWizard II program to search the device and
configure it to let the device work properly again.

4. DC-in Jack
The input power is 12VDC.

Note:

Please use the bundle adapter for the Network Camera. Otherwise, the product

may be damaged.