4 rack mounting – AirLive POE-FSH808PW User Manual

Page 13

Advertising
background image

2. Installation of the Switch

AirLive POE-FSH808PW User’s Manual

8

The relative humidity in the location should not exceed 90% non-condensing humidity.

The distance between the RJ-45 port and the standard network interface should not

exceed 100 meters.

Adequate space should be allowed in front of all the ports, so that each port is easily

accessible for cable connections.

Leave at least 10cm(4 inch) of space around the switch to allow heating dissipation

2.4 Rack Mounting

The POE-FSH808PW can be mounted on a standard size 19-inch rack, which can in turn
be placed in a wiring closet with other equipments.

Before you can mount the switch on the rack, first you must attach the mounting brackets
on both sides of the switch with screws, and then mount it as a unit on the rack.

To mount the unit on a rack, please follow the steps below:

Step 1. First, align the holes on the bracket with the holes on both side of the switch.

Step 2. Insert screws into the holes and then fasten the bracket on one side of the switch

with a screwdriver.

Step 3. Repeat Step 1 and 2 to fasten the bracket on the other side of the switch.

Step 4. Mount the unit on the rack and align the notches on both brackets with mounting

holes on the rack, and then secure the unit with suitable screws.


Fastening the brackets on the switch