5 poe configuration – AirLive POE-FSH808PW User Manual

Page 32

Advertising
background image

4. Web Management

AirLive POE-FSH808PW User’s Manual

27

The broadcast packet is only checked at the selected port and the number of broadcast
packets is counted in every time unit. One time unit is 500 us for 10Mbps speed and 5ms
for 100Mbps. The excessive broadcast packet will be discarded. For those broadcast
packets incoming from the un-selected port, the switch treats it as the normal traffic.

Threshold: Type in the threshold in the range between 1 and 63 to limit the maximum
byte counts, which a port can send or receive in a period of time.

Enable Port: Having ticked the boxes, the port will stop transmitting or receiving data
when their sending byte counts or receiving byte counts reach the defined threshold.

Click

Update to have the configuration take effect.

Example to change one time unit to pps:

The port 1 is 100M port. The one time of it is 500us, it indicates there are 2,000packets can

be sent within one second. While type 10 to port 1, that means 10x2000 packets can be

sent in one second.

4.5.5 POE Configuration

User could know per PoE port out power status in this page and also enable or disable per
port.