Utilities
Temperature Compensation
As air temperature changes, so does the speed of sound. This change can
cause 0.18% drift in distance for every °C change. The TEMPCOMP Mode
allows compensation in the readings for this change. The DCR-WEB contains
an internal thermistor which measures temperature in °F. By turning temperature
compensation on, the effects of temperature changes will be reduced.
MODE
DESCRIPTION
PARAMETERS
TEMPCOMP Temperature
Range = ON-OFF
Compensation
Default = OFF
VIEWTEMP
Displays Detected Range = -20 to +140
Temperature
Reset
If the mode adjustments get scrambled or if the factory preset values are
wanted, Change this mode to 1 and press M-UP or M-DN and all of the
parameters will be “RESET” to their factory defaults.
MODE
DESCRIPTION
PARAMETERS
EXPLANATION
RESET
Reset
Range = 0,1
Calibration
Entering a 1 will RESET the
Controller to Factory