• Wiring
Step 1: Mount sensor so that transducer has a clear path to the target.
Step 2: To obtain access to the terminal strip, remove the front cover by
turning out the 4 screws. This will expose the terminal strip and 2 X 8 character
display.
Step 3: Wires can be pulled into the DCR-WEB through the strain reliefs on
the enclosure.
The screw terminal can be wired using solid or stranded wire between 16 - 20
AWG. Wires should be stripped, leaving a 0.4 in. bare wire.
Follow the legend on the circuit board when wiring. The DCR-WEB should
never be used without the earth ground terminal being connected.
Step 4: Perform an internal check to ensure that all wires are properly
connected and secured.