APG DCR-WEB user manual User Manual
Page 19

Rev. A3, 10/08
DCR-WEB
19
Automation Products Group, Inc.
APG...Providing tailored solutions for measurement applications
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
• Specifications
Operating Range .............. 6 in. to 120 in.
Sample Rate ..................... 40 to 120 msec
Outputs ............................ Isolated 0 to 10 VDC
2 relays (5 A 120 VAC)
Enclosure ......................... Poly-Carbonate
Transducer Type .............. Electrostatic/Ceramic
Ratings ............................. NEMA 4
Operating Temperature .... -20 to 140°F
Internal Temperature
Compensation .................. yes
Accuracy .......................... ± 0.25% of range
Resolution ........................ 0.1 in.
Beam Pattern ................... 8° Electrostatic / 9° Ceramic
Display ............................. 2 line x 8 character alphanumeric LCD
Supply Voltage ................ 110 VAC or 220 VAC
• Dimensions
Controller
Ceramic Transducer
Electrostatic Transducer
7.000"
7.000"
3.50"
2.600"
2.600"
3.000"
3.000"
2"
2"
1.5"