The Calibration parameter is used to adjust the unit for the change in speed of
sound due to environments other than air. For example, units operating in a
heavy fuel or gaseous environment may wish to calibrate the controller output
distance with a measured distance. For most applications, this parameter will
remain at 1.000.
MODE
DESCRIPTION
PARAMETERS
EXPLANATION
Calib
Calibration
Range = 0.000 - 9.999
Default = 1.000
Max Gain
This parameter is used to limit the maximum amount of amplification available
to the micro-processor. This is factory preset at 7 and should not need
adjustment.
MODE
DESCRIPTION
PARAMETERS
EXPLANATION
Max Gain
Max Gain
Range = 1 - 8
Default = 7
Used to limit the
maximum amount of gain
desired in an application.
This setting should be left
at 7.
Allows user to calibrate
controller output distance
with a measured distance.
Usually used for mediums
other than air.