Turntable is making a popping
noise.

One or more roller tubes are misaligned with

respect to the center pin. Each tube should be
perpendicular to the center pin, or the platform
will roll across the roller instead of rolling over
it. Perpendicularity can be checked using a
large square. Call the factory for base
replacement.

PROBLEM

POSSIBLE CAUSE AND SOLUTION

Turntable is difficult to rotate

There may be roller damage. Check the

turntable base rollers for proper alignment and
possible bearing damage. Replace as
necessary.

The load is not evenly distributed on the

platform. Make sure that the center of gravity
of the load is within 10” of the center of the
turntable.

One or more tubes are not sitting vertically on

the base plate. Make sure that each roller
tube is perpendicular to the base plate (it could
h a v e

b e e n

b e n t

s l i g h t l y

d u r i n g

shipping/handling). Call the factory for base
replacement.

The thrust washers are not installed properly.

See Figure 5 in the Installation Section to
ensure that the center pin thrust washers have
been installed properly. Missing washers will
cause the platform to “dish” in the center when
bolted in place.

The center pin-retaining bolt has been over

tightened. The retaining bolt should be backed
off and retightened using no more than 80 ft.
lbs of torque.

If the turntable was provided with detents, the

detent bar may be set too tight. There is an
adjustment screw to lessen the stopping
pressure against the detent pins.