16.

Reinsert the piston into the barrel, taking care not to pinch or nick the new seal.

17.

Slip the bearing assembly into place and align the retainer hole with the slot in
the barrel.

18.

Turn the bearing with the Spanner wrench until the retainer is reinserted
completely.

19.

Pull up the rod and reinstall the upper clevis pin and setscrew.

20.

Reconnect the cylinder hose.

21.

Check that the lag bolts are secure after checking all pins and other mechanical
and hydraulic components.

22.

Restore the oil level (see oil recommendations in the “Routine Maintenance”
section.

23.

Turn on the electrical power and press the “UP” button. It may take a few
seconds to fill the empty cylinders. Raise the tilter to remove the maintenance
block.

24.

Lower the tilter completely and hold the “DOWN” button for 60 seconds to allow
air in the cylinders to bleed back into the tank.

25.

Raise the tilter to 25 – 50% of its full travel, then lower fully holding the “DOWN”
button for an additional 60 seconds. Repeat this step 8 – 10 times.

26.

Check the oil level (see oil requirements).

27.

Clean the oil fill breather cap.

PIPE THREAD SEALANT

Loctite PST #567 pipe thread sealant or equivalent is recommended. Do not use
Teflon tape.
Tape fragments can cause malfunctioning of the hydraulic system.

GENERAL MAINTENANCE

Advertising