Inspect buckle on completed clamp and tap down buckle shroud.







































FRONT VIEW

Completed Free-End Clamp

(Visually inspect lock)

Buckle Shroud

Lock sheared in center
and formed inside
shroud

SIDE VIEW

Completed Free-End

Clamp

Tap down buckle shroud to
complete clamp

Completed clamp
should appear as
shown.

Important: Visually inspect lock formed in band as shown. If lock has slipped under the sheared surface of the
buckle, remove clamp and install a new one at reduced tension by lowering the Drill Clutch torque setting.

Shear Surface

Section View

Good Clamp

Bad Clamp

Lock has slipped back
under sheared buckle
surface