Trouble-Shooting

1. Lock slips down in buckle: Tighten blade mounting screws. If lock on clamp is still not adequate,

reduce tension on tool by setting torque setting on the Drill Dial to a lower number.

2. Drill clutch releases prematurely: Make sure Tool is fully seated on Drill (per page 4). If problem

persists, contact BAND-IT technical support.

Note: To mitigate Drill Clutch wear, do not over-use the Drill Clutch. When tensioning a clamp, let the
Drill Switch go as Tension Block nears its end of travel. Reverse drill and send Tension Block all the way
forward for a second pull on the band.

3. If tool does not cut off on initial setting:

Step 1: Pull trigger of tool after engaging cutter blade.

Step 2: Increase torque setting slightly, and repeat tensioning band and engaging of cutter blade.

Step 3: Repeat steps 1 and 2 until band cuts.

4