Xit6000-ca, Maintenance, 3/8” tie-lok – BAND-IT XIT 6000-CA 3/8 Tie-Lok Tool User Manual
Page 23: Tool
Document # XIT177 Rev E
© Copyright
BAND-IT-IDEX, Inc. 2005
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-3070 USA
P: 1-800-525-0758 F: 1-800-624-3925
23
XIT6000-CA
3/8” Tie-Lok
®
Tool
A) Remove Cutter Blade as described on page 18.
B) Remove the Knife Pin Access Screws. These are
special length screws.
Important: When repairing tools, threaded fasteners
should be secured using Loctite, Red - high strength.
To remove Cutter Knife Pin the Knife Assembly
must be in its uppermost position indicated by the
Cutter Knife Pin in line with the access hole. If not
aligned, connect the tool to the Air Controller
Module. Open the Air Shut-off Valve to
momentarily pressurize the tool. Close the valve
and disconnect the tool from the Air Controller
Module. Then push out the Cutter Knife Pin with
a piece of wire (for example, a bent paper clip).
Once the pin is removed, grasp the Knife
Assembly with a pair of needle-nose pliers and
pull out of tool head. Examine for wear and
replace if needed.
Re-install all parts in reverse order. After the
Maintenance Flip Cover is installed and Quick
Release Pins are in place, apply tension to the
Maintenance Flip Cover Tightening Screw,
torque to 12-15 inch pounds.
Maintenance
Knife Assembly Replacement: