Operation:

When the system calculates a force outside the predetermined range the red LED will be lit,
error message will be appended to output data string, and the voltage at the “9V Out” signal
output will change from 9 VDC to 0 VDC. This condition could be caused by: tension
pressure set incorrectly, an air leak in the tool, cut-off timing set too short, or low air supply
volume to the tool.

Correct the problems as required and cycle the tool by installing a clamp or using the
M28090 device. If the red LED is still lit, continue to look for and correct problems related to
the air system.

Note: Pushing the Reset Button on the Breakout Box will clear an error, return the LED to
green, and reset the voltage at the signal output to 9 VDC. This is not normally needed,
unless the 9V out directly controls a shutoff device to the tool. See page 35 for additional
means to reset the tool.

When the breakout box first detects a connected tool, it will output the tool information: Total
number of cycles and tool serial number.

Example of Data Output

:

Program: X75301 *Revision: C

Clamp # PSI

LBF Tool #

Error

30

11111

31

69.0

359 11111

32 64.8

337 11111

33 58.1 302 11111 LOW
34 72.7 378 11111 HIGH

The suggested operating range is 333-368 LBF.

LBF = The calculated force applied to the clamp tail +/- 15 LBF.

Example:

Clamp number 33 shows a low output and clamp number 34 shows a high output for this
example.

Clamp number 30 shows output when tool is first connected.

*Note: Tool display should be Revision C. Earlier versions can be easily upgraded, contact
BAND-IT Engineering.

Actual ASCII output, items in [ ] are output only if an error is detected: (cycle number) 9
(Pressure) 9 (Force) 9 (serial number) [9 (error)] 10 13