Specification summary, Deltran corporation – Battery Tender Waterproof 800 International - 12V @ 800 mA (PN 022-0150-DL-WH) User Instructions User Manual

Page 4

Advertising
background image

7

AMBER LIGHT ON STEADY (Both models) – Whenever the amber light

is on steady, a battery is connected properly and the charger is charging

the battery. The amber light will remain on until the charger completes the

charging stage.

GREEN LIGHT FLASHING (1.25A only) - When the green light is

flashing, and the amber light is on, the battery is greater than 80%

charged and may be removed from the charger and used if necessary.

Whenever possible, leave the battery on charge until the green light is

solid.

GREEN LIGHT ON STEADY (Both models) - When the green light stops

flashing and burns steady, the charge is complete and the battery can be

returned to service if necessary.

ALTERNATING AMBER & GREEN LIGHTS FLASHING (Both models)

– This is abnormal and most likely indicates that the battery is sulfated.

STATUS INDICATING SYMBOLS: The following symbols are located

next to the 2 status indicator lights, one amber, one green (1.25 A) or

on each side of the single status indicator light that glows either amber

or green (800 mA).

The symbol next to the AMBER light represents a partially

charged battery. The solid band across the bottom is green in

color. The background is yellow. The green area indicates the

charged portion of the battery and the yellow area represents

the uncharged portion.

The symbol next to the GREEN light represents a fully charged

battery. The entire area inside the battery outline is green.

TROUBLESHOOTING CHECK LIST:

1. NEITHER OF THE CHARGER LIGHTS TURN ON AFTER THE AC POWER

PLUG IS CONNECTED TO THE AC ELECTRICAL OUTLET:

For the 1.25A

model:

Check the charger AC power plug connection at the AC electrical outlet.

Verify that the AC electrical outlet is functioning properly by plugging in another
appliance or a voltmeter. For the 0.8 A model, also make sure that the charger output
is properly connected to the battery.

2. THE CHARGER GREEN LIGHT GOES ON IMMEDIATELY WHEN AC

POWER IS APPLIED TO THE CHARGER:

The charger connections at the

battery may be intermittent, the battery may be defective, or the battery might already
be fully charged.

3. CHARGER IS CHARGING BUT THE GREEN LIGHT DOES NOT TURN ON

IN A REASONABLE AMOUNT OF TIME:

The battery may be large and requires

more time to fully charge than originally expected, there may be another appliance
drawing electric power from the battery while it is charging, or the battery may be
defective. Also, a newly purchased battery may not be fully charged and may take
longer to charge initially.

4. THE AMBER LIGHT COMES ON AGAIN AFTER THE GREEN LIGHT

CAME ON.

There may be another appliance drawing electric power from the battery

causing its voltage to drop below the reset level. The battery charger then goes back
into full charge mode. Also, the charger connections at the battery may be intermittent
or the battery may be defective.

8

SPECIFICATION SUMMARY:

Technical Specifications (0.8 Amp or 1.25 Amp Models)

Input Voltage

100 to 240 VAC

Input Frequency

50 / 60 Hz

0.275 or 0.3 Arms @ 100 VAC

Input Current

0.08 or 0.1 Arms @ 240 VAC

Output Current

Bulk Charge

800 mADC Constant

or 1.25 ADC

Absorption Charge

14.5 VDC Constant

Output Voltage

Maintenance Charge

13.2 VDC Constant

Input to Output

2500 VAC

Input to Chassis

2500 VAC

Electrical

Isolation

Output to Chassis

500 VAC

Operating Temperature

-20

°

C to +50

°

C

Enclosure Protection Against

Foreign Object & Water Ingress

IP67

Charger Case Dimensions:

0.8 Amp: 4.25 in (108 mm) L x 2.75 in (70 mm) W x1.5 in (38 mm) H.
1.25 Amp: 5.4 in (137 mm) L x 2.9 in (74 mm) W x1.6 in (41 mm) H.

Note: For both models, allow an additional 1 in (25.4 mm) on each

end of the length dimension for safe bend of AC and DC power cord

strain relief.

Shipping Weight:

0.8 Amp: Approx. 2.0 lbs (0.91 kg)

1.25 Amp: Approx. 2.5 lbs (1.2 kg)

WITH:

Accessories &

Retail Packaging

Acceptable Battery Cell Type, Number, and Ah Capacity

Charger Model Cell Type

Number Ah Capacity

12V, 0.8 Amp

Lead Acid, All

but Gel Cell

6 Cells

Up to 65 Ah

12V, 1.25 Amp Lead Acid, All

but Gel Cell

6 Cells

Up to 95 Ah

DELTRAN CORPORATION

801 U.S. Highway 92 East

DeLand, Florida 32724

Phone 386-736-7900 FAX 386-736-0379

www.batterytender.com

Advertising