6. Testing Performance

Test Shore Power

Connect the shore power cable to the shore power source. Turn

on the shore source to make power available to the boat.

a. Turn the selector switch to

SHORE. No Reverse

Polarity lights should be lit, and power available should

be indicated. If any red Reverse Polarity lights are on,

turn off the shore power circuit breaker and disconnect

the shore cord at the shore source. Either the hot and

neutral or hot and ground wires have been reversed.

Starting at the distribution panel, trace the connections

as far back as necessary to locate the error.

b. If there are no indications of reverse polarity, check to

see that power is available. If the electrical distribution

panel has a meter, verify that shore power is available

and at the proper voltage. If there is no meter, turn

on the load circuit breaker for an AC circuit powering

a convenience outlet and use a voltmeter to verify

that power is available from line to neutral at the plug.

Verify that there is no voltage between ground and

neutral.

Test Generator System

Turn the circuit breaker at the shore source to

OFF. Set the

selector switch to

OFF. The shore power available lights should

all be off. Start the generator and turn the generator breaker to

ON.

a. The power available light for the generator output

should light. The reverse polarity light should be off.

b. There should be no power available indication at the

shore power circuit breaker.

c. Set the selector switch to

GENERATOR. Power

should be available at the power distribution panel. If

the electrical distribution panel has a meter, verify that

power is available and at the proper voltage.

d. There should be no power available lights indicating at

the shore circuit breaker, or the shore indicator of this

panel.

The Purpose of the AC Main Source Selector Panel

Alternating Current (AC) power changes polarity 60 times per second in

the US, Canada and Latin America and 50 times per second in Europe.

This is the frequency of the power and is referred to as Hertz (or the now

outdated term “cycle”). Because of this alternating nature of AC power,

two live sources of AC power, such as shore power and inverter power,

or shore power and a generator, cannot be electrically connected. The

AC Main Source Selector panel is designed to connect two sources of

AC power to a common circuit while preventing both sources from being

connected to the circuit simultaneously.

Related Products from Blue Sea Systems

• High Amperage Fuses and Circuit Breakers for positive feed wires

• High Amperage Battery Switches

• Terminal Blocks and Common Bus Connectors

• AC Distribution Panels

• DC Distribution Panels

• AC and DC Digital and Analog Voltmeters and Ammeters

Useful Reference Books

Calder, Nigel, 1996: Boatowner’s Mechanical and Electrical Manual,

2nd edition, Blue Ridge Summit, PA: TAB Books, Inc.

Wing, Charlie, 1993: Boatowner’s Illustrated Handbook of Wiring,

Blue Ridge Summit, PA: TAB Books, Inc.

Test Shore Connection to Switch

Disconnect the shore power cord from the shore power source

and bring the shore plug aboard to a point close to the switch

panel. Connect the other end of the shore cord to the boat’s

power inlet. Turn ON the shore power circuit breaker between the

inlet and the selector switch. Set the selector switch to OFF.

a. Use an ohmmeter to check for continuity from the shore

ground plug to the green wire at the electrical panel.

b. Check for continuity from the power cord plug neutral

pin to the neutral wire (white typically in US, light blue

typically in Europe) at the selector switch.

[7]

c. Check for continuity between the line pin of the shore

plug and the line wire (typically black in US, brown in

Europe) at the selector switch.

[3]

d. Check that there is a high resistance between

(>1000 Ohms) the neutral conductor and the

grounding conductor.

e. Verify that there is a high resistance between

(>1000 Ohms) between the shore cord plug neutral

pin and line pin. There may be indicator lamps in the

circuit, but no more than that with the selector switch in

the off position.

Verify Switch Selects Shore Input

With the shore cord still disconnected from the shore and

available onboard, and the generator set not operating, set the

load circuit breakers to off, so there is no load at the output side of

the selector switch.

a. Verify that the there is a high resistance between the

line and neutral of the load side terminals of the

selector switch. There may be indicator lamps still

attached, so it may not read open circuit.

[2] to [6]

b. Set the selector switch to SHORE. The ohmmeter

should still indicate a high resistance.

c. Short the line pin to the neutral pin of the shore cord

and verify that the line and neutral at the load side of

the selector show a low resistance when these are

shorted and a high resistance when they are not.

Verify the Generator Wiring

Turn the generator circuit breaker to OFF and set the selector

switch to the generator position. All load circuit breakers should

still be off. Leave the shore input circuit breaker in the on

position.

a. Verify that there is a high resistance (>1000 Ohms)

from the line to neutral.

[2] to [6]

b. Verify that there is a low resistance from the neutral to

ground at the load connections.

[6] to [ground]

c. With the generator still not running, close the generator

circuit breaker at the generator. Verify that there is a

now a low resistance from line to neutral where the

generator windings are now connected across the

circuit.

d. Verify that there is still a high resistance from neutral to

ground and neutral to line at the shore power plug.

Set the Selector switch to

OFF, turn the shore power breaker

to

OFF, and leave the load panel circuit breakers in the OFF

position. Complete the mounting of the switch.

Set your multimeter to volts.

5. Apply circuit labels and mount panel

Apply a label for the circuit form the 10 basic labels provided. If the

appropriate label is not included individual labels are available form

Blue Sea Systems for specific applications. Refer to the label order

form included with the panel for a complete listing of individual labels.

Fasten the panel to the mounting surface using the panel mounting

screws supplied with the panel.

Advertising
This manual is related to the following products: