Installation instructions, Caution – Blue Sea Systems 7717 ML-RBS Remote Battery Switch with Manual Control Auto-Release - 24V User Manual

Page 2

Advertising
background image

LED

1
2
3

+8

-7

LED

1
2
3

+8

-7

2 AMP MIN.

A

B

START

BATTERY

2155

REMOTE CONTROL SWITCH

SPDT, ON-ON

ENGINE

NOTE: For optional SPST

switch connections

Wire connections are the same

as the SPDT, ON-ON except

the Ground is omitted.

No Connection

orange

green
brown

CONTROL

(red)

GROUND (black)

LED OUTPUT

(yellow)

+12V DC

(red)

1

2

3

6

4

2 AMP MIN.

A

B

START

BATTERY

2155

REMOTE CONTROL SWITCH

SPDT, ON-ON

ENGINE

NOTE: For optional SPST

switch connections

Wire connections are the same

as the SPDT, ON-ON except

the Ground is omitted.

GROUND (black)

LED OUTPUT

(yellow)

+12V DC

(red)

CONTROL

(red)

1.965"

49.91mm

1.010"

25.65mm

.595"

15.10mm

1.125"

28.58mm

TEST CUT

HOLE IN
ACTUAL
CENTER

1.450"

36.83mm

0.830"

21.08mm

Installation Instructions

Installation Instructions

Mounting

Install as close as possible to battery bank. To avoid corrosion to connecting wires and terminals, mount in

a dry and protected location. Avoid mounting directly above vented lead acid batteries so that the Remote

Battery Switch is not exposed to corrosive gasses expelled from the batteries.

High Current Primary Circuit Connections

(stud terminals A and B)

For help selecting the appropriate wire size and circuit protection rating, go to www.bluesea.com and click the

Circuit Wizard quick link.
NOTE: Stud terminals A and B are interchangeable. A battery connection is required on one terminal

for device operation

To connect high current circuit wires:

1. Connect the battery bank to one of the stud terminals marked A or B.

2. Connect the load to the other stud terminal marked B or A.

3. Torque the high current terminal stud nuts to 140 in-lbs (15.5 N•m) maximum.

NOTE: If switching an inverter, windlass, bow thruster, etc., the circuit wires must have circuit protection to

comply with ABYC guidelines. Wires used for engine starting do not require circuit protection.

Control Circuit Connections

(wires contained in the wire harness)

NOTE: The Remote Battery Switch is designed to be controlled by a SPDT or SPST switch.

Use minimum 16 AWG wire for the Control Circuits. For help selecting the appropriate wire size for the load

cables, go to www.bluesea.com and click the Circuit Wizard quick link.

To connect the SPDT Remote Control Switch 2155:

1. Connect pin 3 and pin 8 to +12V or +24V Power available when Remote Battery Switch is OFF. (fused)

2. Connect the red control wire to switch pin 2.

3. Connect pin 7 to yellow wire.

4. Connect pin 1 to ground or negative.

4.50"

114.30mm

3.00"

76.20mm

5.47"

138.94mm

3.75"

95.25mm

2.03"

51.56mm

1.90"

48.26mm

1.03"

26.16mm

Guarantee

Blue Sea Systems stands behind its products for as long as you own them.
Find detailed information at www.bluesea.com/about.
For customer service, call 800-222-7617.

These instructions are intended to provide assistance with the installation of this product, and are

not a substitute for a more comprehensive understanding of electrical systems. We strongly

recommend that a competent electrical professional perform the installation of this product.

The illustrated wiring diagram represents a common installation and is not meant to be a guide for wiring

a specific vessel. The wiring diagram shows a single battery bank installation.

Disconnect all negative battery connections before beginning the installation.
All unused control wires should be carefully insulated from each other and from accidental contact

using heat shrink tubing or electrical tape. External contact or shorting between control wires can lead

to malfunction.

CAUTION

Tinned Wire Termination

Deutsch DTM Connector Termination

Advertising