Troubleshooting

Troubleshooting

On occasion your machine may not operate as expected.

Use the checklist below before you decide that a mechanical or electrical failure has occurred.
Checklist

1. Are the main disconnect switches, breakers, or motor overloads turned ON?
2. Are the main water and steam supplies turned ON?
3. Are the drain valves closed?
4. Are the spray pipes and rinse nozzles clean?
5. Are the spray pipes in the proper locations?
6. Are the pump intakes clean?
7. Are the scrap screens clean and in place?
8. Are the thermostats correctly adjusted?
9. Are the high limit temperature thermostats reset?
10. Are the doors fully closed?
11. Are the conveyor shut-off and drive assemblies in operating condition?
12. Are the chemical supplies adequately filled?
If a problem still exists after verifying the checklist, refer to the following

CONDITION

CAUSE

SOLUTION

Conveyor will not run

Door not closed ................................... Make sure doors are fully closed

Door safety switch faulty .................... Contact your service agency

Start switch faulty ............................... Contact your service agency

Main switch OFF ................................ Check disconnect

Control panel power switch OFF ........ Flip switch ON

Conveyor shut-off shelf operated........ Move shelf toward tunnel of machine

Motor overload protector tripped ........ Reset overload in control cabinet

Green start button not pressed ............ Press green start button