Troubleshooting – CHAMPION EUCCW Series User Manual

Page 27

Advertising
background image

19

CONDITION

CAUSE

SOLUTION

A single pump will not run

Motor overload tripped ....................... Reset overload in control cabinet

Defective motor

Contact your service agency

Low or no water

Main water supply is turned off .......... Turn on house water supply

Drain valves are open.......................... Close all drain valves

Doors are not fully closed ................... Close doors

Faulty fill valve ................................... Contact your service agency

Stuck or defective float switch............ Free float /Contact service agency

Cross-flow piping misadjusted/

clogged ................................................ Adjust cross-flow setting/Clean piping

Clogged strainer at supply

connection ........................................... Clean strainer screen

PRV misadjusted or defective............. Readjust pressure setting or replace PRV

Continuous water filling

Stuck or defective float switch............ Free float/Contact service agency

Fill valve will not close.......................

Clean valve,repair or replace valve

Drain valves open................................ Close drain valves

Wash/Rinse tank

Incoming water temp.

Raise incoming temperatureis low

temperature low

at machine low..................................... 140°F minimum for 40°F rise booster

110°F minimum for 70°F rise booster

180° F minimum without booster

Defective thermometer ........................ Check or replace

Defective thermostat ........................... Readjust setting or replace

Defective electric heater element ........ Check or replace

Low steam pressure or volume ........... Check steam supply pressure

Defective steam trap............................ Check or replace

Defective solenoid valve ..................... Check or replace

Prewash tank temperature

Incoming cold water temperature

Lower incoming water temperature

is too high (Optional Cold

too high................................................ to maximum of 65°F

Water thermostat Only)

Defective cold water thermostat ......... Check or replace

Insufficient pumped spray

Clogged pump intake screen ............... Clean

pressure

Clogged spray pipe.............................. Clean

Scrap screen full .................................. Must be kept clean and in place

Low water level in tank

Check drain valves

Pump motor rotation incorrect ............ Reverse wires L1 and L2 in control cabinet

Defective pump seal ............................ Contact service agency

Insufficient final rinse or

Faulty pressure reducing valve

no final rinse

(PRV) .................................................. Clean or replace

Improper setting on PRV .................... Set Flow pressure to 20-22 PSI

Clogged rinse nozzle or pipe .............. Clean

Improper water line size...................... Installer must change to proper size

Clogged “Y” strainer........................... Clean or replace

Troubleshooting