Danger warning caution warning – COATS ProGuard Leverless Plus Tire Changer User Manual

Page 17

Advertising
background image

Operation Manual

-

COATS PRO GUARD PLUS

- 17

10.3_Commissioning

- Connect the machine to the electrical mains, which must have line fuses and an effi cient grounding system, pur-
suant to current standards. It must also be connected to an automatic differential circuit breaker calibrated at 20 A.

NOTE: If the machine is supplied without an electrical plug, the user shall fi t one (at least 20A) that is suitable for
the voltage of the machine and that complies with current standards.

- Connect the machine to the compressed air system using the fi tting on the lubricator at the back of the machine.

When moving the machine around to position it initially, or if it is moved in the future to a different
location, it must be disconnected from the electrical and pneumatic power sources.

Before you connect the machine electrically, check the nameplate fi tted on it to make sure the elec-
trical power supply to which it will be connected matches the electrical arrangement of the manu-
facturer.

Work on the electrical system, must be carried out by professionally qualifi ed personnel.

The manufacturer is not liable for machine damages caused by the incorrect electrical connection.

DANGER

WARNING

CAUTION

WARNING

- Loosen the control panel bracket locking cap screw and pivot cap screw, adjust it to a convenient position for tha
operation, then tighten the cap screw.

Advertising