Main power, auxiliary power and motor power, Motor power – ElmoMC Gold Line Digital Servo Drives-Gold Whistle User Manual
Page 35

Gold Whistle Installation Guide
Installation
MAN-G-WHIIG (Ver. 1.208)
35
4.7. Main Power, Auxiliary Power and Motor Power
The Gold Whistle receives power from main and auxiliary supplies and delivers power to the
motor.
4.7.1.
Motor Power
Note:
When connecting several drives to several similar motors, all should be wired in an
identical manner. This will enable the same settings to run on all drives.
Pin
Function
Cable
Pin Positions
Brushless
Motor
Brushed DC
Motor
PE
Protective earth
Motor
Motor
M1
Motor phase
Motor
N/C
M2
Motor phase
Motor
Motor
M3
Motor phase
Motor
Motor
Table 9: Motor Connector
Connect the M1, M2, M3 and PE pins on the Gold Whistle in the manner described in Section
4.3.2.1. The phase connection is arbitrary as the Elmo Application Software (EAS) will
automatically establish the proper commutation during setup. However, if you plan to copy the
setup to other drives, then the phase order on all the drives must be the same.
Figure 5: Brushless Motor Power Connection Diagram