Port c feedback output – ElmoMC Gold Line Digital Servo Drives-Gold Whistle User Manual
Page 77

Gold Whistle Installation Guide
Technical Specifications
MAN-G-WHIIG (Ver. 1.208)
77
5.4.3.
Port C Feedback Output
Feature
Details
Emulated output
•
A, B, Index
•
Differential
Interface
•
RS-422
Output current capability
Maximum output current: I
OH
(max) = 2 mA
High level output voltage: V
OH
> 3.0 V
Minimum output current: I
OL
= 2 mA
Low level output voltage: V
OL
< 0.4 V
Available as options
•
Emulated encoder output of any sensor on
Port A or Port B
•
Daisy chain Port A or Port B
•
Emulated encoder output of internal
variables
•
Emulated encoder outputs of the tachometer
•
Emulated encoder outputs of the
potentiometer
Maximum frequency
f
MAX
: 8 MHz pulses/output
Edge separation between A & B
Programmable number of clocks to allow
adequate noise filtering at remote receiver of
emulated encoder signals (default 2 MHz)
Index (marker)
Length of pulse is one quadrature (one quarter of
an encoder cycle) and synchronized to A&B