User i/os, Digital inputs (j1) – ElmoMC Gold Line Digital Servo Drives-Gold Whistle User Manual
Page 54

Gold Whistle Installation Guide
Installation
MAN-G-WHIIG (Ver. 1.208)
54
4.10. User I/Os
The Gold Whistle has six programmable digital inputs (J1), four digital outputs (J1) and one
analog input (J2).
4.10.1. Digital Inputs (J1)
Each of the pins below can function as an independent input. The inputs conform to the TTL
level.
Pin (J1) Signal
Function
3
INRET1-6
Programmable inputs 1 - 6 return
4
IN1
High speed programmable input 1
(event capture, home, general purpose, RLS, FLS, INH)
5
IN2
High speed programmable input 2
(event capture, home, general purpose, RLS, FLS, INH)
6
IN3
High speed programmable input 3
(event capture, home, general purpose, RLS, FLS, INH)
7
IN4
High speed programmable input 4
(event capture, home, general purpose, RLS, FLS, INH)
8
IN5
High speed programmable input 5
(event capture, home, general purpose, RLS, FLS, INH)
9
IN6
High speed programmable input 6
(event capture, home, general purpose, RLS, FLS, INH)
Table 17: Digital Input Pin Assignments
See Figure 23 for the TTL connection.