ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual
Page 111

Reported Fault
Value
Bit
Motion processor inhibited (internal software problem)
0x800,000
23
Cannot auto-calibrate current offsets.
0x10,000,00
0
28
Cannot start motor.
0x20,000,00
0
29
Modulo limit exceeded (internal software problem)
0x80,000,00
0
31
Table 3-27: Reasons for Automatic Motor Shutdown
0x8000 0x4000 0x2000 Meaning
0 0 0 OK.
0
0
1
Under-voltage. The power supply is shut down or
it has too high an output impedance.
0
1
0
Over-voltage. The voltage of the power supply is
too high, or the servo drive did not succeed in
absorbing the kinetic energy while braking a load.
A shunt resistor may be required.
0 1 1 Reserved.
1 0 0 Reserved.
1
0
1
Short circuit. The motor or its wiring may be
defective, or the drive is faulty.
1
1
0
Temperature. Drive overheating. The environment is
too hot, or lacks heat removal. There may be a large
thermal resistance between the drive and its
mounting.
1 1 1 Reserved.
Table 3-28: Bits 13 - 15 of MF Report
Attributes:
Type:
Status report, Integer, Bit-field
Scope:
Program, RS-232, CANopen
Restrictions: None
Unit modes: All
SimplIQ:
Modified – see notes
SimplIQ for Steppers Command Reference Manual
Alphabetical Listing
MAN-STECR (Ver. 1.1)