Hx - hexadecimal mode – ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual
Page 80

HX - Hexadecimal Mode
Purpose:
Sets or resets the hexadecimal mode for reporting integer parameter values.
With HX=0, integers are reported as decimal numbers.
With HX=1, integers are reported as hexadecimal numbers.
HX does not affect floating-point reports.
The HX parameter allows easy reading of the digital inputs (IP), servo drive status
(SR), motor faults (MF), recorder settings (RC) and other variables that have the bit-
field attribute.
The HX parameter is not required for setting values. The commands BH=1024 and
BH=0x400 are equivalent, as 0x400 equals its decimal equivalent of 1024.
Attributes:
Type: Parameter,
Integer
Source: RS-232
Restrictions: None
Default value: 0,
Volatile
Range: [0,
1]
Unit modes: All
Activation: Immediate
SimplIQ: Similar
SimplIQ for Steppers Command Reference Manual
Alphabetical Listing
MAN-STECR (Ver. 1.1)