ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual
Page 64

Error
Code
Error String / Description
Example / Remedy
164
EC command (not an error).
For internal use.
165
An attempt to access serial flash while busy.
Failure on reading serial flash memory,
possibly due to a hardware problem.
Contact Technical Support.
166
Out of modulo range.
XM[1]=-1000, XM[2]=1000 and
PA=2000 is an error because the
modulo range is [-1000…999].
Therefore, the position of
PA=2000 can never be reached.
167
Infinite loop in for loop - zero step
k=1:0:10; causes this error.
168
Speed too large to start motor.
MO=1 or motor started with Enable switch
while motor was rotating too quickly.
Starting a running motor may fail
if the back EMF is too high and
induces an immediate excessive
motor current.
Table 3-10: Processing Error Codes
Attributes:
Type:
Status report, Integer
Source: RS-232,
CANopen
Restrictions: None
Unit modes: All
SimplIQ: Modified
See also:
MF
,
SR
SimplIQ for Steppers Command Reference Manual
Alphabetical Listing
MAN-STECR (Ver. 1.1)
56