Limit ranges – ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual
Page 21

Limit Ranges
The following table lists the value ranges for defining the limits of the system.
Subject Values
Position counter ranges
Main position counter is subjected to a modulo
counting with the following ranges:
XM[1]: Lowest value
XM[2]: Highest value
Range: [-5x10
8
…5x10
8
] counts
Auxiliary position counter is limited to:
YM[1]: Lowest value
YM[2]: Highest value
Range: [-5x10
8
…5x10
8
] counts
Velocity range
Range for Quadrature Encoder:
[-40,000,000…40,000,000] counts/sec
Range for other feedbacks:
[-80,000,000…80,000,000] counts/sec
EF[1]: Filter for main velocity sensor
EF[2]: Filter for auxiliary velocity sensor
Acceleration/Deceleration ranges
Range: [100…1,000,000,000]
Stop deceleration range
Range: [100…1,000,000,000]
Torque limits
Range of torque command is subjected to the
following limits:
CL[1], PL[1]
Range: [-MC…MC]
Note:
The multiplication of the PWM frequency
reduces the torque limit.
Table 3-1: Limit Ranges
SimplIQ for Steppers Command Reference Manual
Alphabetical Listing
MAN-STECR (Ver. 1.1)
13