7 analog input dialog box – ElmoMC SimplIQ Servo Drives Composer User Manual User Manual
Page 65

2. Select the String # (command) that you wish to overwrite and in the String Name
text box, enter a name for the command (button).
3. In the adjacent String Value text box, type the command string. Be sure to separate
multiple commands with a semicolon ( ; ) and add a semicolon at the end of the
string.
4. Repeat steps 2 and 3 to program additional commands.
5. When you complete your command definition, click OK.
You may save the set of commands as a text file by clicking Save To File, and
subsequently recall the file by clicking Load From File.
3.3.2.7 Analog Input Dialog Box
This dialog box is used to set the gain values for the analog input, according to operating
mode (velocity or current).
Fill in the dialog box as follows:
1. From the Operating Mode drop-down list, select the mode for working with the
controller:
Software: Disables analog input.
Elmo Composer User Manual
Using the Composer
MAN-COMPUM (Ver. 1.9)
3-15