17

Desire XTI Series v1.6.0 User Manual

Installation on a Wall

The Wall Mount Bracket accessory for the D40/D60 XTI fixture provides a stable mounting

position for the fixture, while providing a wire way for a clean and functional installation to

walls and other vertical surfaces.

Refer to the D40/D60 XTI Wall Mount Installation Instructions.

Power and Data Cabling Requirements

Power

The D40/D60 XTI fixture operates on AC power, 100 to 240VAC/50-60Hz. The fixture must

be connected to a non-dimmable power source in order to avoid damage to its internal

power supply and other electrical components. Dimming will damage the fixture and void

the warranty.

The fixture is completely pre-wired at the factory and there is no need for entry into the

housing.

Refer to D40/D60 XTI Installation Instructions for detailed information about installation.

Europe

North America

Mains

Brown

Black

Live

Blue

White

Neutral

Yellow/green

Green

Ground

C A U T I O N :

The fixture must be grounded and wired in accordance with national, state and

local electrical codes. Failure to do so may result in serious personal injury.

Advertising