Installing the lamp

1.

Disconnect power to the Source Four HID PARNel CE before installing the lamp.

2.

Loosen the knurled bolt on the back of the lamp housing and pull the housing out.

3.

Holding it by the base, remove the lamp from its box.

N o t e :

To avoid premature lamp failure, do not touch the lamp glass with your fingers. If you

touch the lamp during installation, clean it carefully with rubbing alcohol and a clean, lint-

free cloth before operation.

4.

Insert lamp base into socket assembly. (

Figure 3

)

5.

Push down on the lamp base until the lamp seats firmly.

6.

Reinstall the lamp housing by aligning the bolt hole and tightening the knurled bolt.

C A U T I O N :

Replace the lamp if it becomes damaged or thermally deformed.

Improperly installed lamps will cause premature lamp and socket

failures.

Ballast information

The only acceptable voltage is 120V (+/- 10%) 50/60HZ.

The standard operating current is 1.5 Amps.

The standard inrush current is <14 Amps.

Room ambient temperature should not exceed 40ºC.

The lamp ignition voltage is 4.5Kv, non-hot restrike.

The ballast case temperature should not exceed 75ºC.

The ballast is attached to the Source Four yoke by two screws and is non-removable.

WARNING:

DO NOT power the Source Four HID PARNel CE with a dimmable power supply.

Dimming will damage the ballast and void the warranty.