Flint & Walling Commander Pro 75 User Manual

Page 10

Advertising
background image

10

95 North Oak Street • Kendallville, IN 46755

Copyright 2012. All Rights Reserved.

SMART RESET

If a motor underload fault condition occurs, the most likely

cause is an over pumped or dry well. To allow the well to

recover, the CP WATER SubDrive will wait 30 seconds

to 5 minutes, determined by duration of the previous run

time, before restarting the motor. For example, the first

time the fault occurs, the CP WATER SubDrive will wait

30 seconds before attempting to restart the pump. If the

system would then run for 1 minute and an underload

fault reoccurs, the controller will wait 4 minutes before

attempting to restart the pump. This schedule allows for

the minimum off-time possible based on the recovery time

of the well.

0

6.0

5.0

4.0

3.0

2.0

1.0

0.0

1

2

3

4

5

6

7

8

Run Time (Min.)

Off T

ime (Min.)

IL0025

CP Water Pump Underload “Smart Reset”

EXTENDED INPUT VOLTAGE RANGE:

The CP WATER SubDrive is designed to provide full

performance with an input supply voltage of 200 to 260V

AC. If the input supply voltage drops below 200V AC,

SubDrive will continue to run at reduced output while

flashing an undervolt warning signal flash code #2. Output

power will continue to decrease with supply voltage until

it reaches the trip level near 130V AC and show flash

code #2. The CP WATER SubDrive will automatically

restart (at reduced output) when the supply voltage rises

to approximately 145VAC. When supply voltage restores

200VAC the undervolt warning signal will stop flashing

and full output performance will resume.

Subdrive 75

Description

Part #

Pressure Switch

020627

100 ft. Pressure Switch Cord

020628

4.5 Gal. Tank

020629

Controller - Standard

020143

Controller - NEMA 4

022956

Motor

137458

Pump end for CP7507

CP7507RP

Pump end for CP7510

CP7510RP

Pump end for CP7519

CP7519RP

Pump end for CP7527

CP7527RP

Pump end for CP7535

CP7535RP

Subdrive 100

Description

Part #

Pressure Switch

020627

100' Pressure Switch Cord

020628

Controller - Standard

023045

Controller - N4

023046

Motor 2 HP

137462

Pump end for CP10007

CP10007RP

Pump end for CP10010

CP10010RP

Pump end for CP10019

CP10019RP

Pump end for CP10027

CP10027RP

Pump end for CP10035

CP10035RP

Pump end for CP10055

CP10055RP

Subdrive 150

Description

Part #

Pressure Switch

020627

100 ft. Pressure Switch Cord

020628

14 Gal. Tank

132661

Controller - Standard

020475

Controller - NEMA 4

022957

Motor

139424

Pump end for CP15007

CP15007RP

Pump end for CP15010

CP15010RP

Pump end for CP15019

CP15019RP

Pump end for CP15027

CP15027RP

Pump end for CP15035

CP15035RP

Pump end for CP15055

CP15055RP

Pump end for CP15085

CP15085RP

Advertising
This manual is related to the following products: