1. Read these warnings and instructions carefully.

Failure to follow them could cause serious bodily

injury and/or property damage.

2. Follow all local electrical and safety codes as well

as the National Electrical Code (NEC) and the

Occupational Safety and Health Act (OSHA).

3. The power supply should be a separate circuit,

independent of all other circuits. Be sure it is

equipped with a fuse and disconnect box of

ample capacity.

4. For fire protection, the power supply should be

free of any building, preferably on a direct line

from the transformer. In the event of fire, the

wires will not be destroyed and the water supply

not cut-off.

5.

Always disconnect power source before

performing any work on or near the motor or its

connected load. If the power disconnect point is

out-of-sight, lock it in the open position and tag

it to prevent unexpected application of power.

Failure to do so could result in fatal electrical

shock.

6.

DO NOT handle pump with wet hands or when

standing in water as fatal electrical shock could

occur. Disconnect main power supply before

handling pump for any reason.

7. Shut off power source when voltage drops 10%

below the rated voltage of the motor.

8. Protect the power cable from coming in contact

with sharp objects, oil, grease, hot surfaces or

chemicals.

DO NOT kink the power cable. If

damaged replace immediately.

9.

NEVER leave the control box, fused disconnect

switch, or covers open (either partially or

completely) when not being worked on by a

competent electrician or repairman.

10. Always use caution when operating electrical

controls in damp areas. If possible, avoid

all contact with electrical equipment during

thunderstorms or extreme damp conditions.

11. Install all electrical equipment in protected area to

prevent mechanical damage which could produce

serious electrical shock and/or equipment failure.

12. Pump is designed to pump cold ground water

that is free of air or gases. Decreased pump

performance and life expectancy can occur if the

ground water is not cold (86F/30C) or contains air

or gases.

13. Pump and controls must be securely and

adequately grounded as specified in section 250-

43 item (A) of the U.S.A. National Electric Code

(NEC) and Section 26-954 Canadian Electrical

Code. Failure to do so could result in a fatal

injury.

14.

DO NOT use this pump to pump flammable

liquids such as gasoline, fuel oil, kerosene, etc.

Failure to follow the above warning could result in

property damage and/or personal injury.

WARNING: The pump is intended for use in a well.

Motor frame must be connected to power supply

ground or fatal electrical shock may result. Do not use

this pump in swimming pools.

WARNING: This product contains chemicals known

to the State of California to cause cancer and birth

defects or other reproductive harm.

NOTE: Pumps with the “CSA” mark are tested to UL

standard UL778 and certified to CSA standard C22.2

No. 108.

OWNERS GUIDE TO

INSTALLATION AND OPERATION OF

4” — 35-85 GPM and

6” — 50-250 GPM

8” — 325-400 GPM

SUBMERSIBLE PUMPS

130582

WARNING

IMPORTANT SAFETY INSTRUCTIONS

RULES FOR SAFE INSTALLATION AND OPERATION

FW1184

0309

Supersedes

0408

Advertising