Flint & Walling Centrifugal Packages - end suction centrifugal pumps User Manual

End suction centrifugal pumps, Owners guide to installation and operation

Advertising
background image

1

95 North Oak Street • Kendallville, IN 46755

Copyright 2011. All Rights Reserved.

GENERAL SAFETY INFORMATION
1. Follow all local electrical and safety codes, as

well as the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA).

2. Replace damaged or worn wiring cord immediately.
3. Do not kink power cable and never allow the cable

to come in contact with oil, grease, hot surfaces, or
chemicals.

4. Protect the power cable from coming in contact with

sharp objects.

5. Be careful when touching the exterior of an

operating motor - it may be hot enough to be painful
or cause injury.

6. Make certain that the power source conforms to the

requirements of your equipment.

7. Always disconnect power source before performing

any work on or near the motor or its connected load.
If the power disconnect point is out-of-sight, lock it in
the open position and tag it to prevent unexpected
application of power. Failure to do so could result in
fatal electrical shock.

8. Do not handle the pump with wet hands or when

standing in water as fatal electrical shock could
occur. Disconnect main power before handling unit
for ANY REASON!

9. Unit must be securely and adequately electrically

grounded. This can be accomplished by wiring the
unit to a ground metal-clad raceway system or by
using a separate ground wire connected to the bare
metal of the motor frame or other suitable means.

10. WARNING: Risk of electric shock. This pump has

not been investigated for use in swimming pool
areas.

11. WARNING: This product contains chemicals known

to the State of California to cause cancer and birth
defects or other reproductive harm.

INSPECTION AND STORAGE
1. Immediately upon receipt of shipment, inspect and

check the shipping document and report to the
Transportation Company’s local agent any damage
or shortage. If the unit is received sometime before
it can be used, it should be inspected, recrated and
stored in a dry location.

2. Unless otherwise specifically agreed, all capacity,

head and efficiency guarantees are based on factory
test when handling clear, cold, fresh water at a
temperature not over 85°F.

LOCATION
IMPORTANT:
In installations where property damage
might result from an inoperative or leaking pump due
to power outages, discharge line blockage or any other
reason, a back-up system(s) and/or warning system(s)
should be used.
1. Locate pump as close to the fluid source as possible.

CAUTION: The unit should be placed where the motor

and electrical components are protected from the

weather and extremes of heat, humidity and below

freezing temperatures.

2. Mount unit in a dry location that is easily accessible

for inspection and maintenance. Allow ample
clearance around the unit for free air circulation.

OWNERS GUIDE TO INSTALLATION

AND OPERATION

END SUCTION CENTRIFUGAL PUMPS

READ THESE INSTRUCTIONS CAREFULLY
Read these installation instructions in detail before

installing your pump. Be sure to check the following:
1. Be certain the motor is connected for the correct

line voltage being used (check motor nameplate).

2. Be certain the pump is completely primed before

starting. Otherwise damage may occur to the

seal.

Every pump is tested before leaving the factory, and

its performance depends largely on the installation.

FW0300

0111

Supersedes

0309

134984

Advertising