Dimensions in inches – Flint & Walling Centrifugal Packages - end suction centrifugal pumps User Manual

Page 2

Advertising
background image

2

95 North Oak Street • Kendallville, IN 46755

Copyright 2011. All Rights Reserved.

If a dry location is not available mount it on a
foundation well above the wet floor.

WARNING: Do not handle the pump with wet hands or

when standing in water as fatal electrical shock could

occur. Disconnect main power before handling unit

for ANY REASON!
3.

Pumps incorporate a discharge port on the pump
casing that can be adjusted in 90° increments. If
necessary adjust the discharge port to accommodate
the specific application. Pump performance will not
be affected by the position of the discharge port.

SUCTION LIMITATIONS
1. Units are non self-priming. Normally after being

primed the total suction lift of the pump is 15 feet.

2. Where liquids at or near their boiling points are

being handled, the supply must be located above
the suction, so that the available NPSH will be
greater than that required by the unit.

PIPING
1. Do not use the pump as support to the piping. The

pipe must be independently supported near the
pump so that no strains will be transmitted to the
unit. Failure to do so will cause premature pump
failure and will void the warranty.

2. Suction and discharge sizes are selected for proper

performance of the pumping unit and are not

intended to determine the suction and discharge
pipe sizes. Pipe sizes must be determined by the
user based on the system requirements.

3. Install both a union and a gate valve (not furnished)

on the suction and discharge side of the pump for
service convenience.

CAUTION: Do not use a globe or other restricting

type of valve at the discharge. Globe valves seriously

restrict the capacity of the pump.
4.

All joints and connections should have pipe sealing
compound (male threads only) applied and drawn
up tightly.

CAUTION: The entire system must be air and water

tight for efficient operation.

SUCTION PIPING
1. Suction piping should be short in length, as direct

as possible, and never smaller in diameter than the
pump suction opening.

2. Use galvanized piping, rigid plastic or other suitable

pipe that will not collapse under suction.

3. The suction pipe should slope upward to the pump

inlet. A horizontal suction line must have a gradual
rise to the pump. Any high point in the pipe will
become filled with air and thus prevent proper
operation of the pump. When reducing the piping
to the suction opening diameter use an eccentric

DIMENSIONS in INCHES

Figure 1

C22000 SERIES

Catalog Number

HP

Motor

Frame

Size

A

B

C

D

E

F

G

J

K

1 Phase 3 Phase

SINGLE STAGE 3500 RPM

C22131

3

182JM

4.50

7.50

10.24

4.50

10.81

4.06

12.12

19.49

3.44

C22133

3

145JM

5.00

5.50

9.49

3.50

9.81

4.06

10.50

17.87

3.44

C22151

5

184JM

5.50

7.50

10.24

4.50

10.81

4.06

12.12

20.49

3.44

C22153

5

182JM

4.50

7.50

10.24

4.50

10.81

4.06

12.12

20.49

3.44

TWO STAGE 3500 RPM

C22231

3

182JM

4.50

7.50

12.49

4.50

10.81

6.31

12.12

20.49

3.44

C22233

3

145JM

5.00

5.50

11.74

3.50

9.81

6.31

10.50

20.12

3.44

C22251

5

184JM

5.50

7.50

12.49

4.50

10.81

6.31

12.12

22.74

3.44

C22253

5

182JM

4.50

7.50

12.49

4.50

10.81

6.31

12.12

22.74

3.44

C22273

7-1/2

184JM

5.50

7.50

12.49

4.50

10.81

6.31

12.12

22.74

3.44

Dimensions shown above are approximate maximum dimensions for standard pumps equipped with open drip