WATER TREATMENT

®

Automatic Water Filters

Filter T

ank

Assembly

Sanitary Drain, Floor Drain or Laundry

Tubs are acceptable.

Do not make a direct connection to the drain.

An air gap must

be present.

Cold filtered water inlet 30 p.s.i. minimum pressure 1” minimum pipe size

Maximum drain pipe elevation above drain port is 5 ft.

High Pressure W

arning:

If feedwater pressure is known to be above 125 psi, it is strongly recommended that a pressure reducing valve be installed at this point.

Unfiltered water to Sprinklers and any dersired unfiltered fixtures

Ground Strap

Filter W

ater Outlet

Manual Outlet V

alve

(optional)

110-125 V

olt

Continuous Power Supply

Transformer

Manual Bypass V

alve

(Normally Closed) (optional)

Manual Inlet V

alve

(optional)

Drain Port

Drain line 1/2” ID diameter minimum size

Connection to sanitary sewer line (optional)

Air gap device

Sanitary sewer line

Drain T

rap

Drain

IL1037

Typical W

ater CBW Installation