D. PRESSURE TEST THE INSTALLATION

The plumbing system can now be checked for any
possible leaks
1. Open the water supply inlet valve very slowly. Once

the mineral tank is full of water, slowly open the
outlet on the bypass. Open a faucet down stream
from the filter & allow the air to escape. DO NOT
INITIATE A BACKWASH UNTIL MEDIA IS SATURATED.

2. Allow water to run until clear. CHECK FOR LEAKS!
3. Plug the unit in.
4. Make sure the power cord is plugged into a properly

grounded wall receptacle.

E. PROgRAMMINg THE CONTROL VALVE
How To Set Time Of Day

The user can set the time of day. Time of day should only
need to be set initially, and after extended power outages
or when daylight saving time begins or ends and at the
time of start-up. If an extended power outage occurs, the
time of day will flash on and off which indicates the time
of day should be reset.

STEP 1U - press

SET

HOUR

.

STEP 2U - Current Time (hour):
Set the hour of the day using

or

buttons. AM/PM toggles

after 12.

STEP 3U - press

SET

HOUR

button to

complete and return to display
mode.

How To Change Time of Backwash and Days
Between Backwashes

STEP 1 - From normal mode,

press

SET

HOUR

&

buttons

simultaneously for 3 seconds and
release.
STEP 1A - Backwash Time:
Set the clock to the hour the
backwash should occur by using the

and

buttons. An arrow will point to p.m. after 12 (factory

default is 1 a.m.). Press

SET

HOUR

to go to step 1B.

STEP 1B - Setting Days Between Backwash:
Use the

and

buttons to set the days between

backwashes (factory default is 3 days).

Press

SET

HOUR

to return to Normal mode.

Backwash Mode

Typically a system is set to backwash at a time of low
water usage. An example of a time with low water usage
is when a household is asleep. If there is a demand for
water when the system is backwashing, untreated water
will be used.
When the system begins to backwash, the display will
change to include information about the step of the
backwash process. The system runs through the steps
automatically and will reset itself to provide treated
water when the backwash has been completed.

Manual Backwash

Sometimes there is a need to
backwash the system, sooner than
when the system calls for it, usually
referred to as manual backwash.

To initiate a manual backwash at
the preset delayed backwash time,
press and release

and

simultaneously. An arrow point on
the display indicates that the system
will backwash at the preset delayed backwash time. If you
pressed the

and

buttons in error, pressing the

buttons again will cancel the request.

To initiate a manual backwash immediately, press and
hold the

and

buttons simultaneously for four

seconds. The system will begin to backwash immediately.
The request cannot be cancelled. You can manually step
through individual cycles by pressing the

button until

display reaches normal mode.
Power Loss
If the power goes out for less than two hours, the system
will automatically reset itself. If an extended power
outage occurs, the time of day will flash on and off which
indicates the time of day should be reset. The system will
retain the other information entered by your plumbing
professional.

SET

HOUR

REGEN

MIN. FILL

REGEN

HOUR

TIME-HOUR
PM
DAYS TO

REGEN

3

OR

SET

HOUR

REGEN

MIN. FILL

REGEN

HOUR

TIME-HOUR
PM
DAYS TO

REGEN

1

IL1042

SET

HOUR

REGEN

MIN. FILL

REGEN

HOUR

TIME-HOUR
PM
DAYS TO

REGEN

3

IL1075

SET

HOUR

REGEN

MIN. FILL

REGEN

HOUR

TIME-HOUR
PM
DAYS TO

REGEN

3

OR

IL1074

SET

HOUR

REGEN

MIN. FILL

REGEN

HOUR

TIME-HOUR
PM
DAYS TO

REGEN

3

IL1075

Advertising
This manual is related to the following products: