9

remier

remier

roducts

roducts

P

P

P

P

WATER TREATMENT

®

Automatic Water Filters

IL1043

IL1044

IL1045

DIAgNOSTIC MODE

Supply

Water Exits

Supply

Water Enters

Figure 3

Diagnostic:
The inlet handle points in the direction of flow and the outlet handle
points to the center of bypass valve, system water pressure is allowed
to the control valve and the plumbing system while not allowing
water to exit from the control valve to the plumbing.

ByPASS OPERATION

IL1046

No

Water Exits

Supply Water is shut off

from the house and the

valve

SHUT OFF MODE

Figure 4

Shut Off:
The inlet handle points to the center of the bypass valve and the
outlet handle points in the direction of flow, the water is shut off to
the plumbing system. If water is available on the outlet side of the
softener it is an indication of water bypass around the system (i.e. a
plumbing connection somewhere in the building bypasses the system).

“Untreated”

Water Exits

Supply

Water Enters

Figure 2

Bypass:
The inlet and outlet handles point to the center of the bypass, the
control valve is isolated from the water pressure contained in the
plumbing system. Untreated water is supplied to the plumbing
system.

NORMAL OPERATION

“Treated”

Water Exits

Supply

Water Enters

Figure 1

Normal Operation:
The inlet and outlet handles point in the direction of flow indicated
by the engraved arrows on the control valve. Water flows through
the control valve during normal operation and this position also al-
lows the control valve to isolate the media bed during the regenera-
tion cycle.

Bypass Valve

The bypass valve is typically used to isolate the control
valve from the plumbing system’s water pressure in order
to perform control valve repairs or maintenance. The
bypass valve is particularly unique in the water treatment
industry due to its versatility and state of the art design
features. The bypass valve incorporates four positions
including a diagnostic position that allows service
personal to work on a pressurized system while still
providing untreated bypass water to the facility or
residence. Its completely non-metallic, all plastic, design
allows for easy
access and serviceability without the need for tools.

The bypass body and rotors are glass filled Noryl and the
nuts and caps are glass filled polypropylene. All seals are
self-lubricating EPDM to help prevent valve seizing after
long periods of non-use. Internal o-rings can easily be
replaced
if service is required.
The bypass consists of two interchangeable plug valves
that are operated independently by red arrow shaped
handles. The handles identify the flow direction of the
water. The plug valves enable the bypass valve to operate
in four positions.