Automatic water filters – Flint & Walling CCF Series Air Induction Water Treatment Systems User Manual

Page 5

Advertising
background image

5

remier

remier

roducts

roducts

P

P

P

P

WATER TREATMENT

®

Automatic Water Filters

3. Locate in correct relationship to other water

treatment equipment (See Figure 1).

4. Allow sufficient area around the equipment for

service.

FACTS TO REMEMBER WHILE PLANNINg
yOUR INSTALLATION

1. All installation procedures MUST conform to local and

state plumbing codes.

2. If lawn sprinkling, a swimming pool or geothermal

heating/cooling are to be treated by the Chemical
Free filter, a larger model filter MUST be selected to
accommodate the higher flow rate demands.

3. IMPORTANT: Always use Teflon tape on threaded

plastic fittings. NEVER use pipe dope, as it will
deteriorate the plastic fittings.

CHECK WATER PRESSURE

Minimum water pressure required at the inlet of the
filter is 20 psi. IF PRESSURE IS OVER 100 PSI, A PRESSURE

REGULATING VALVE MUST BE INSTALLED TO REDUCE
WATER PRESSURE.
NOTE: Pressure regulating valve must be installed in
water line ahead of the air induction assembly.

CHECK PUMPINg RATE OF WELL PUMP

The pumping rate of your well pump must be sufficient
to properly backwash the filter. Check backwash flow rate
required for specific filter model.

Water Pressure

Low

_____ psi

High

_____

psi

Pumping Rate _________ GPM

Figure 1 - Standard Installation

FILTERED WATER

FILTERED

SOFT WATER

WATER

SOFTENER

WATER

FILTER

PRESSURE

TANK

PRESSURE

SWITCH

WELL WATER

FROM PUMP

IL1039

Advertising
This manual is related to the following products: