4 configurations – Garland HO IN 1800 INDUCTION TEMPERATURE CONTROLLED BUILT-IN HOLD-LINE User Manual

Page 10

Advertising
background image

Installation

RTCSmp Built-In Temperature Controlled Hold-Line


10

Part # 4532286 Rev 3 (6/10/14)

(H)

IMPORTANT

Minimum clearance for heat plate under counter surface: 100mm / 3.94”

(I)

Cable for operation unit connecting to the induction generator, MAX 300cm / 118”.

(J) Cables for coil and sensors.

IMPORTANT

Always route sensor and communication cables separately and away from the coil cables.

4.4

Configurations

One Induction Generator can power up to four (4) Heat Retaining Plates. You need to install two (2) control units
for any configurations with 2 to 4 Heat Retaining Plates.

Model

Configuration
(Heat Retaining Plate(s), Control Switch(s), and Induction Generator are shown)

HO IN 450

One switch controls one heat retaining plate.

One (1) heat retaining plate, one (1) generator and one (1)
control unit.

HO IN 900

Two switches; each controls only one heat retaining plate.

Two (2) heat retaining plate, one (1) generator and two (2)
control units.

HO IN 1350

Two switches; one switch controls one heat retaining plate and
the other switch controls two plates.

Three (3) heat retaining plate, one (1) generator and two (2)
control units.

HO IN 1800

Two switches; each controls two heat retaining plates.

Four (4) heat retaining plate, one (1) generator and two (2)
control units.