Maintenance – General Machine Products 89004 Portable Powered Duct Rod Pusher User Manual

Page 19

Advertising
background image

Page 19 of 40

General Machine Products Co., Inc.

6. MAINTENANCE

To insure reliable service from your Rod Pushing Machine, we recommend the unit be com-
pletely serviced every 6 months.

TRACTOR DRIVE

Inspect the chain drive blocks for wear each week.

CHECK

the chain tension weekly and adjust if necessary with the two

external adjustment screws (do not over tension). The chain should
slightly lift off the chain guides, when pulled at the center by finger.

THE CHAIN SHOULD BE LUBRICATED EACH TIME USED

by application of Metaflux

spray grease 70-88. This is achieved by running the rod pushing machine at about 130ft/min
without any rod and carefully inserting the spray tube from the canister into the holes on the
operator side of the aluminum drive castings (2). The spray tube should be carefully inserted
until the chain can just be felt and then withdrawn about 3/4 – 1” and spraying for approxi-
mately 1 second.

DO NOT OVER LUBRICATE, AS THIS MAY LEAD TO THE DRIVE BELTS BEING
CONTAMINATED WITH LUBRICANT.

If contamination does result, wipe the belts clean thoroughly before attempting any pushing
operation. (This is based on normal use where the chains are not exposed to excessive
contamination).

Bottom frame chain lubrication
point

Top frame chain lubrication point

Advertising