9. PROCEDURE FOR THE OUTFEED AND INFEED SUB DUCT
CLAMP


INFEED AND OUTFEED SUB DUCT CLAMP:
a. To adjust the sub duct clamp bracket in either direction, release the adjusting knob locking

ring and turn the knob placed directly under the sub duct clamp.

b. Select the adjustment required – using the increment gauge on the side of the unit.
c. Tighten the locking ring to prevent any movement during installation.

10. MONTHLY SERVICE – CHECK LIST

a. Remove the drive chains from the pusher unit. Check both of the chains for excessive

wear. Replace, if required – and lubricate with the spray grease provided.

b. Remove any debris from the housings.
c. Check the chain supports slide bars for excessive wear and lubricate with the spray

grease provided. Replace, if required.

d. Check all other moving parts e.g. bearings, shafts, sprockets etc. – and lubricate.
e. Check main jacking screw – and lubricate.
f. Check all hydraulic fittings and check for leaks.
g. Check the electrical lead for external damage.
h. Check the electrical plug and sockets.
i. Check the function of the electronic control module.
j. Check the operation of the emergency stop button.
k. Check the operation of the rod measuring device.
l. Check the wheel tire pressures and free rotation. Inflate and lubricate, as necessary.
m. Clean the infeed rod guide bracket.

n.

Complete service history record.