Programming Parameters for CUB5R counter/rate meter fitted to Rod
Pushing machines – REV 2

The device must be wired and installed into the machine prior to programming.

The Duct Rod Pusher is fitted with CUB5R, reflective version
The DIP switch positions are as follows:
1. ON
2. OFF
3. ON
4. ON

Please see the attached CUB5 Programming
Overview attached to this document.

a. Press and hold SEL for 2 seconds to enter

programming mode

b. Enter the Pro-Code – 222 by pressing RST to change numbers

and SEL to skip to the next number.

c. Once correct Press and Hold SEL for 2 seconds
d. Pro-no should now be flashing, press RST
e. Press RST to move through the various sections 1-input, 2-rate 3-dsplay, sections 4 and 5

will be unavailable, see the next page of instructions for the parameters required.

f. Press SEL to enter that section
g. To change the value of a parameter press RST
h. Press SEL to move to the next parameter (You will have to hold for 2 seconds on certain

parameters).

i.

When all the parameters in the section have been scrolled through you will return to the
Pro-no display, press RST to scroll to another section else press SEL to exit programming
mode.